BP12-180 12V180Ah AGM Battery

Product Description

Model: BP12-180
BRAVA 12V 180Ah VRLA SLA batteries are superior high quality, high performance, multi-purpose batteries designed to provide dependable primary and back-up power in domestic and commercial applications. to provide reliable performance in the Uninterruptible Power Supply, Telecom, Information Technology and Emergency Power Supply Systems. The battery can be used in PV systems. Valve Regulated Lead Acid.

Voltage : 12v
Capacity : 180Ah
Size : 523*239*218*222mm
Weight : 56.5kg
Terminal : M8

Tags 

Share This Page

agm battery in mowers

12v180ah AGM battery General Features & benefits:

High Performance
With low internal resistance and efficient discharge characteristics, BRAVA BP batteries can be applied to many fields, both in cycle and stand by use.

Maintenance Free
During the service life, there is no need to check the level of the electrolyte or to add water. The gases produced during electrolysis are almost completely recombined to water (up to 99%)
through an effective reaction between hydrogen and oxygen.

Safety Valve Design
Excessive gas produced by overcharge or an incorrect charging method is released through the safety valve, which detects rising internal pressure and allows gas to exit; then automatically
reseals.

Separator Technology
The Absorbent Glass Mat (AGM) separator, used in the BRAVA batteries, is a highly porous material, which achieves maximization of oxygen diffusion and facilitates the reaction of active materials in the plates.The separator also maintains a constant distance between the positive and the negative plates and immobilizes the electrolyte, so that the possibility of acid leakage is minimized.

Performance on Wide Temperature Range
BP batteries operate within a wide range of temperature while the optimum temperature for the operation of the battery is 20ºC – 25ºC.

Low Self-discharge Rate
Using a lead / calcium grid alloy, the self–discharge is minimum. The battery can be stored for 9 months under normal conditions (20ºC – 25ºC) with no permanent effect on the capacity
or the expected service life.

Leak and Spill Proof Container
The construction of the BP battery guarantees that no electrolyte leakage can occur from the terminals or case. A highly resistant plastic material is used, available in either standard ABS (UL94 HB) or flame retardant type (UL94 V-0).

Float Service Life
The nominal service life is 12 years in float / standby applications (20ºC).

Multi-position Usage
The sealed construction of the battery allows perfect operation in any position (vertical or horizontal but not completely inverted position).

Product Application

    • alarm systems,
    • UPS power supplies,
    • cash registers,
    • emergency lighting.
    • cash registers,
    • wheelchairs and golf carts,
    • mowers,
    • toys,
    • cleaning machines.
    • replacement 12v180Ah cp12180 PS-12180 SP12-120 ES180-12

Tips: more detail application,for AGM battery application.

Standards & Certifications

  • Compliance with IEC 60896 standards, EU Battery Directive
  • UL, CE Certified
  • Manufactured in ISO45001,ISO 9001 and ISO 14001 certified production facilities

AGM Battery Topic: | Feature | | Applications | | Related Products |


 

12v180Ah AGM Battery Specifications

Rated Voltage
12V
Nominal Capacity 180Ah
(C10 ,1.80V/cell)
Dimension Length
523±2mm ( 20.92inches)
Width
239±2mm (9.56 inches)
Container Height
218±2mm (8.72 inches)
Total Height
222±2mm (8.88 inches)
Weight
Approx.56.5 Kg (124.3 Ibs)
Terminal
F12( M8)
Container Material
ABS
Rated Capacity(25℃) 190.80 Ah
(20hr, 1.75V/cell)
180.20 Ah
(10hr,1.75V/cell)
154.50 Ah
(5hr,1.75V/cell)
136.50 Ah
(3hr,1.75V/cell)
Max. Discharge Current
1800A (5s)
Internal Resistance(25℃)
Approx 3.0mΩ
Operating Temp. Range Discharge
-15~50℃ (5~122℉)
Charge
-20~40℃ (-4~104℉)
Storage
-15~40℃ (5~104℉)
Nominal Operating Temp.Range
25±3℃ (77±5℉ )
Cycle Use Initial Charging Current less than 45A. Voltage 14.1V~14.4V at 25℃ (77℉)Temp. Coefficient -4mV/℃
Standby Use Initial Charging Current less than 45A. Voltage 13.6V~13.8V at 25 ℃ (77℉)Temp. Coefficient -3mV/℃
Effect of temp. to Capacity 40℃ (104℉)
103%
25℃ ( 77℉)
100%
0℃ ( 32℉)
86%
Self Discharge BP series batteries may be stored for up to 6 months
at 25℃(77℉) and then a freshening charge is required.
For higher temperatures the time interval will be shorter

 

Battery Charging/Discharge Curve

Charge Characteristics
Discharge Characteristic
agm battery charging curve
agm battery discharge curve
Cycle Life in Relation to Depth of Discharge
Temperature vs Float Life
agm battery cycles curve
agm battery temperature curve
Capacity Curve At Different Temperature
Self Discharge Characteristics
agm battery capacity temp curve
agm battery storage curve

Battery Structure Diagram

BP12-180 12V180AH LAYOUT
BP12-180 12V180AH LAYOUT

Constant Current Discharge Data Sheet (@25ºC) Unit: A

End Voltage(V) 10min 15min 30min 1h 1.5h 2h 3h 5h 8h 10h 20h
1.60V 441 349 196 114 91 77 47.3 32.9 22.5 18.9 9.84
1.65V 422 332 187 113 89 75 46.6 32.2 22.2 18.7 9.75
1.70V 402 316 178 109 87 73 45.5 31.4 21.8 18.6 9.64
1.75V 382 302 169 107 86 72 44.7 30.9 21.3 18.4 9.54
1.80V 364 287 162 105 84 70 43.6 30.0 20.9 18.2 9.45

Constant Power Discharge Data Sheet (@25ºC) Unit: W

End Voltage(V) 10min 15min 30min 1h 1.5h 2h 3h 5h 8h 10h 20h
1.60V 4934 4088 2531 1475 1077 805 600 387 293 227 122
1.65V 4700 3895 2409 1440 1049 786 586 378 288 224 121
1.70V 4476 3709 2295 1404 1023 766 571 369 282 222 119
1.75V 4263 3532 2186 1369 998 747 557 360 277 220 118
1.80V 4059 3363 2082 1336 975 729 543 350 271 218 117